TOP > Advanced Glass > Organic+Inorganic hybrid antimicrobial
Hybrid IONPURE is inorganic and organic mixed grade, which show anti-fungus efficacy at lower dosage level.
- High Safety!
- Good Heat-resistance!
Be able to add into plastic applications - Broad utility
Be able to add into many types of applications including coatings
Test method: ISO 22196/JIS Z 2801 Tested bacteria: Escherichia coli
| Sample | Number of living bacteria | Antimicrobial activity value against Blank |
Reduction % |
|
|---|---|---|---|---|
| At beginning | After 24 hours | |||
| 1. BLANK SAMPLE | 2×105 | 2×107 | - | - |
| 2. HYBRID IONPURE 0.4% Treated Sample | 2×105 | < 1×102 | > 5.3 | > 99.999 |
Test method: ISO 22196/JIS Z 2801 Tested bacteria: Staphylococcus aureus
| Sample | Number of living bacteria | Antimicrobial activity value against Blank | Reduction % |
|
|---|---|---|---|---|
| At beginning | After 24 hours | |||
| 1. BLANK SAMPLE | 1×105 | 1×106 | - | - |
| 2. HYBRID IONPURE 0.4% Treated Sample | 1×105 | < 1×102 | > 4.0 | > 99.990 |
*Stein: Aspergillus niger NBRC6352 *Test method: JIS Z 2911 B method
| Sample | 1st week | 2nd week | 3rd week | 4th week |
|---|---|---|---|---|
| 1. BLANK SAMPLE | 2 | 2 | 3 | 4 |
| 2. HYBRID IONPURE 0.4% Treated Sample | 0 | 0 | 0 | 0 |
Indication of test result
| Labeling | Fungal thread growth status |
|---|---|
| 0 | No growth of fungal thread was observed visually or by a microscope observation |
| 1 | Invisible to naked eyes. Growth was observed by a microscope. |
| 2 | Growth of fungal thread is minimum. Growth status is < 25% of total sample area |
| 3 | Growth of fungal thread is moderate. Growth status is 25-50% of total sample area |
| 4 | Fungal thread is well grown. Growth status is 50-100% of total sample area |
| 5 | Fungal thread is grown aggressively. Sample is covered by fungus fully. |